Airway management is critical in the care of mechanically ventilated patients, directly impacting treatment efficacy and prognosis. Disposable Catheter Mount as connectors between the anesthesia/ventilator circuit and the patient, primarily used to extend the breathing circuit or facilitate procedures such as suctioning. Their introduction significantly enhances clinical efficiency and quality of care, making them an essential tool in airway management. Undisoffers a series of catheter Mount, including corrugated, expandable, and smoothbore designs. Below are the key advantages of our products:
♦ Maintains Airway Patency:Features a dedicated suction port sealed by a piston when not in use. During suctioning, the catheter can be inserted through this port without disconnecting the patient from the ventilator, enabling simultaneous mechanical ventilation and suctioning. This design effectively prevents hypoxemia associated with suctioning procedures.

♦ Enhances Clinical Flexibility and Efficiency:different portfolio with 360 degree double swivel elbow connectors and available in various lengths (15cm, 20cm, 30cm). Expandable catheter provides greater maneuverability during patient repositioning, prone positioning ventilation, bed adjustments, bedside tracheostomy, patient transport for diagnostic tests, inter-departmental transfers, or inter-facility transfers. This minimizes circuit traction on the endotracheal tube, significantly reducing the risk of unplanned extubation and potentially preventing 50% to 78% of artificial airway-related incidents. one-way design silicone cap is highly praised by bronchoscopy teams, reducing contamination from expelled secretions during tube withdrawal and minimizing the risk of fluid-borne transmission.

♦ Ensures Treatment Safety and Efficacy: Manufactured from high-quality, low-compliance materials (≤10ml/kPa per meter of tubing length) to minimize additional gas compression volume and airflow resistance. Low dead space volume helps control ineffective ventilation. The patented cap design provides a double seal against leaks. Standard ISO 22mm or 15mm connectors ensure compatibility with breathing circuits, masks, and endotracheal tubes
♦ Reduces Ventilator-Associated Pneumonia (VAP) Risk:When suctioning is performed using a catheter mount, the ventilator remains connected to the endotracheal tube. This maintains a relatively closed system, preventing direct exposure of the patient's airway to the ambient environment, thereby significantly reducing the risk of cross-contamination and pathogen entry.
♦ Improves Patient Comfort: Lightweight design reduces traction on the patient's artificial airway, enhancing comfort and minimizing the risk of device-related pressure injuries. Our smooth softer tubing material minimizes pressure on the patient's body and reduces agitation-related injuries potentially occurring during ICU wake-up protocols.
♦ Superior Material and Structural Safety: Features internal support pillars at connection points for enhanced flexibility and effective crack prevention, addressing common clinical feedback concerns. The tube end incorporates a butterfly + diamond pattern design to increase grip and prevent slippage during handling by clinicians. The smoothbored tube variant effectively reduces condensation build-up risk. All three tube types feature transparent walls for continuous monitoring of condensation and secretions. The tubing wall structure resists kinking and occlusion, ensuring consistent airway patency.